3. Service and maintenance

All adjustment, conversion, startup and maintenance operations described below must only be carried out by Qualified Per-
sonnel (meeting the professional technical requirements prescribed by current regulations) such as those of the Local After-
Sales Technical Service.
FERROLI declines any liability for damage and/or injury caused by unqualified and unauthorised people tampering with the
unit.

3.1 Adjustments

Gas conversion

The unit can operate on Natural Gas or LPG and is factory-set for use with one of these two gases, as clearly shown
on the packing and on the dataplate. Whenever a different gas to that for which the unit is arranged has to be used, a
conversion kit will be required, proceeding as follows:
1. Remove the casing.
2. Loosen the gas valve fixing ring "A".
3. Undo the three fixing screws "B" and remove the gas valve "C".
4. Replace the gas valve "D", positioning it inside the gasket "E", with that contained in the conversion kit. Refit the
parts and check the tightness.
5. Modify the parameter for the type of gas:
6. Apply the label, contained in the conversion kit, near the dataplate.
7. Using a combustion analyser connected to the boiler fume outlet, make sure the CO
boiler operating at max. and min. output, matches that given in the technical data table for the corresponding type
of gas.
20
Downloaded from
www.Manualslib.com
put the boiler on standby
press the DHW buttons (details 1 and 2 - fig. 1) at the same time for 10 seconds: the display shows "P01" flash-
ing.
press the DHW buttons (details 1 and 2 - fig. 1) at the same time to set the parameter 00 (for natural gas) or 01
(for LPG).
press the DHW buttons (details 1 and 2 - fig. 1) at the same time for 10 seconds.
the boiler will go back on standby
manuals search engine
C
D
E
B
fig. 24 - Gas conversion