GFK Wall mount 150 – 206 mm
Wall anchor 100 – 150 mm for GFK-substructure
Wall anchor 150 – 200 mm for GFK-substructure
Wall anchor 200 – 270 mm for GFK-substructure
Wall anchor 270 – 400 mm for GFK-substructure
The following must be observed while installing these GFK
wall mounts:
– The surface on which the bracket is screwed, must be completely plain.
– There should be no burrs, otherwise this could lead to the breaking of GFKs while
tightening the screws.
– The fixing screws must be fixed with washers with a minimum diameter of 36 mm.
Maximum tightening torque: 59 Nm; pre-tension force: 26.24 kN;
– The adjusting screws on the bracket itself must be tightened with a maximum torque
of 20.9 Nm and a pre-tension force of 9.28 kN.