Herunterladen Inhalt Inhalt Diese Seite drucken

Error Messages - Leister MISTRAL PREMIUM Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für MISTRAL PREMIUM:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7

Error messages

Display
Designation
Thermocouple
Heating element
temperature too
high
Undervoltage
Device temperature
too high
Contact a Leister Service Center
Cause of error
Thermocouple connection
Thermocouple is defective
Heating element is faulty
Air intake blocked
Stainless steel filter blocked
Air outlet blocked
Wrong nozzle mounted
Wrong nozzle definition
Mains voltage < 20% of the
nominal voltage
Device defective
Ambient temperature higher
than specified
Air intake temperature higher
than specified
Air intake blocked
Stainless steel filter blocked
Air outlet blocked
Wrong nozzle mounted
Wrong nozzle definition
Elimination of error
Check thermocouple connection
Contact a Leister Service Center
Replace heating element
(p. 14)
Check air intake
Clean stainless steel filter
Check air outlet
Replace nozzle
Check nozzle definition
(p. 15)
Check nominal voltage
Contact a Leister Service Center
Reduce ambient temperature
Reduce air intake temperature
Check air intake
Clean stainless steel filter
Check air outlet
Replace nozzle
Check nozzle definition
(p. 15)