Herunterladen Inhalt Inhalt Diese Seite drucken

Leister MISTRAL PREMIUM Bedienungsanleitung Seite 28

Vorschau ausblenden Andere Handbücher für MISTRAL PREMIUM:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
Description of MISTRAL SYSTEM display
Symbol
Heating element is faulty
Activate device protection
(Overheating heating element/device protection)
Undervoltage
Increase temperature
Active blower
Field for displaying the target and actual values.
This is a four-digit segment display without decimal points.
The bar display symbolizes the blower speed at 5 levels. At the same time, it appears in % (1 P–100 P)
Blower speed 100% max.
Change heating element
Changing the heating element may be done only by a trained technician or under
supervision by such.
1
Allow the device to cool down. MISTRAL System automatically shuts down.
2
Disconnect the power cord from the mains.
3
Remove the four attachment screws (13) .
4
Remove the heating element pipe (4), Mica Tube, seal and heating element.
5
Remove the heating element from the packaging.
6
Slide the heating element, Mica Tube and heating element pipe (4) on.
7
Install the heating element pipe (4) with four attachment screws (13) .
8
Connect the power cord to the mains. The nominal voltage, specified on the device must match the mains voltage.
1
5
28
2
6
Symbol
Contact a Leister service center.
Cooling process
Standby
Reduce temperature
Indicator field for displaying units or informati-
on for the service menu
Blower speed 1 % min.
3
7
4
8

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mistral system

Inhaltsverzeichnis