Herunterladen Inhalt Inhalt Diese Seite drucken

Connection To The Power Supply; Installation Diagram - Foster 7380645 Installation

Glaskeramik-induktionskochfeld
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39

CONNECTION TO THE POWER SUPPLY

Installation diagram

Model Supply Voltage / Frequency Number of phases
7380645
7381645
7381245
7382645
7383645
7384645
The appliance may ONLY be connected by an authorized qualified technician.
Electric system protection should comply with all relevant regulations.
The connection clips can be accessed when the connection clip covers are opened /
removed.
Before connecting the appliance, make sure the voltage indicated on the rating plate is
consistent with the voltage in your home network. Connection voltage should be checked
by a qualified technician using a corresponding measuring device!
The rating plate with basic information is attached on the lower side of the appliance.
In order to make a fixed connection to the mains, insert an all-pole circuit breaker
between the appliance and the mains. This device shall have a contact separation in all
poles, providing full disconnection under overvoltage category III conditions.
The current conducting and isolated parts must be protected from any possibility of direct
contact.
Before any intervention, disconnect the appliance from the power mains. Connect the
appliance in compliance with the electric connections diagram supplied; make sure the
relevant network voltage is observed!
The ground wire should be connected to the clip indicated by the earth symbol.
The mains cable should be fed through the fastening clip which protects it from being
accidentally pulled out.
After connecting the appliance, turn on all cooking zones / heaters for approximately
three minutes to make sure they are operating correctly.
Incorrect connection may destroy parts of the appliance, making the warranty void!
Connection cable on the back of the appliance should be led in such way that it DOES
NOT touch the appliance back wall, as this part will get very hot during operation.
The appliance is generally configured to the maximum available power, shown in the
technical data table. It's possible to set an operating mode with power limitation. This
setting can be made at the time of installation or subsequently by a specialized
technician. See chapter on power limitation setting.
Use cables type: H05V2V2-F
LIVE
L1 – L2 – L3
EARTH
NEUTRAL
N1 – N2
220-240 V~ 50/60 Hz
220-240 V~ 50/60 Hz
380-415 V ~ 50/60 Hz
220-240 V~ 50/60 Hz
380-415 V ~ 50/60 Hz
BROWN – BLACK - GREY
GREEN / YELLOW
BLUE
Power cable section
1 phase + N
3 x 2,5 mm2
1 phase + N
3 x 4 mm2
2 phases + N
4 x 2,5 mm2
1 phase + N
5 x 2,5 mm2
3 phases + N
5 x 1,5 mm2
25
Connection

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

73816457381245738264573836457384645

Inhaltsverzeichnis