Herunterladen Inhalt Inhalt Diese Seite drucken

Mode Of Operation; Intended Use; Foreseeable Misuse; Safety Devices - HEYLO PF1000 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für PF1000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mode of operation

The device sucks in ambient air through the air in-
take and pumps it out through the air outlet. First
stage and main filter are installed in front of the air
intake. The preliminary filter (first filter stage) filters
out coarse dust up to 3 µm and the main filter (sec-
ond filter stage) fine dust and airborne particles up to
1 µm.
In recirculating or exhaust air mode the device can
be operated using hosing connected to the intake
and outlet.
The device may be installed inside or outside the
space or room the air in which is to be cleaned.
Vacuum pressure and air extraction can be gener-
ated in rooms/spaces to be renovated by connecting
air hosing.
The filter class HEPA-H14 per DIN EN 1822 and
dust class H per DIN EN 60335 means the device is
suitable for filtering out certain biological agents
such as mould spores and other harmful sub-
stances. The air change rate required depends on
the type of harmful substance.
All applicable laws and employers' liability insurance
rules must be adhered to in the process.
See also
 Intended use
[
33]
14.2.1

Intended use

The device is intended solely for use in cleaning air
in closed rooms or spaces at atmospheric pressure
under non-explosive conditions.
Use of the device as intended predicates operators
having read and understood the operating instruc-
tions and adhering to same. Intended use also in-
cludes adherence to the operating conditions (see
Operating conditions
[
31]). The device must be
tested and serviced at regular intervals.
EN
The device is solely intended for industrial and com-
mercial use.
Any other use is considered improper. Improper use
will result in all warranty claims becoming void.
See also
 Technical details
[
46]
14.2.2

Foreseeable misuse

The following types of misuse can be envisaged:
– Cleaning air in rooms/spaces that are not closed,
or outdoors;
– cleaning air without adhering to the specified
minimum spacing and operating conditions.
14.3

Safety devices

NOTICE
The following safety devices is listed in the device
overview in the chapter General description
Persons can be seriously injured on the device if the
safety devices are not properly installed and set. Do
not modify, dismantle or take any of the safety de-
vices out of operation. All the safety devices must be
freely accessible at all times.
Familiarize yourself with all the safety equipment to
prevent, or at least minimise, damage to tangible as-
sets and/or injuries to persons.
Protective grilles preventing access are installed on
the air intake and air outlet.
The feet ensure that the device remains fixed in
place.
Separating protective devices
Separating protective devices prevent or hinder di-
rect access to the rotating or moving parts of the de-
vice. It has no influence on the movement of device
components. Such equipment may only be removed
Air cleaner PF1000
[
32].
33 / 50

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

1110897

Inhaltsverzeichnis