Hydraulic
Fluid Return
to Tank
Hydraulic
Fluid Inlet
Solenoid Valve
(Items 34*© & 35)
Pressure Reducing
Valve (Item 38)
generated in the pump cylinder chamber, the grease is forced
into the pump cylinder. Simultaneously, grease is discharged
through the outlet of the pump. The volume of grease during
intake is twice the amount of grease output during one cycle.
During the upstroke, the inlet check closes, and one half of
the grease taken in during the previous stroke is transferred
through the outlet check and discharged to the outlet port.
Typical output of the pump is shown on page 4.

Appropriate Use

All pump models are exclusively designed to pump and
dispense lubricants using hydraulic power.
The maximum specifi cation ratings should not be
exceeded.
Any other use not in accordance with instructions will
result in loss of claims for warranty and liability.
HYDRAULIC PUMP PERFORMANCE SPECIFICATIONS
Test conducted with Alvania NLGI # 2 Grade Grease
Grease Output
Cubic inches/min. (cm³/min.)
Hydraulic Flow Input
Temperature F
1 gpm
2 gpm
3 gpm
(Temperature C)
(4 l/min)
(8 l/min)
(11 l/min)
80
7
14
21
(27)
(115)
(229)
(344)
40
7
14
21
(4)
(115)
(229)
(344)
20
6
13
17
(-7)
(98)
(213)
(279)
0
6
11
15
(-18)
(98)
(180)
(245)
-10
5
7
8
(-23)
(82)
(115)
(131)
-20
4
6
8
(-29)
(66)
(98)
(131)
*Solenoid valve with manual override standard on Model 85247, 85670 and 85675 optional on other models.
** 85610 Operating Temperature, ° F(°C) is -70 to 150 (-57 to 65)
Form 403626
FlowMaster™ Rotary Driven Hydraulic Pump
Illustration 1
1,000 psi Backpressure
(70 bar)
4 gpm
5 gpm
6 gpm
7gpm
(15 l/min)
(19 l/min)
(23 l/min)
(26 l/min)
28
34
40
45
(459)
(557)
(656)
(737)
28
33
38
41
(459)
(541)
(623)
(642)
22
28
32
36
(361)
(459)
(594)
(590)
19
23
27
30
(310)
(376)
(442)
(491)
9
10
12
13
(148)
(164)
(197)
(213)
10
12
14
15
(164)
(197)
(229)
(245)
Flow Control
Valve (Item 39)
Pressure Gauge
(Item 32)
Vent
Valve
Pump Performance and Specifi cation
Supply inlet hydraulic pressure,
maximum, PSIG (bar) -
Operating working hydraulic
pressure , PSIG (bar) -
Hydraulic Inlet Flow,
GPM (l/min) -
Pump Ratio with manifold - 9:1 at low inlet pressure
Operating Temperature, ºF (ºC)-
Operating Voltage, VDC -
Hydraulic Inlet Port, In -
Tank Return Port, In -
Pump Outlets, In -
Maximum Hydraulic
Fluid Temperature, ºF, (ºC) -
Weight, Lbs (Kg) -
Do not exceed 3,500 PSIG (241 bar) maximum supply inlet
hydraulic pressure. Exceeding the rated pressure may result
in damage to system components and personal injury.
Hydraulic Motor
(Item 42)
Material
Outlet
3,500 (241)
300 to 450 (20 to 32).
Up to 7 (28)
(300 to 350 psi [20 to 25
bar]) and low inlet fl ow
(below 2 gpm [7 lpm])
Pump ratio approaches
11.0:1 ratio at higher
inlet pressure and fl ow.
-20 to +150 (-29 to 65)**
24
SAE 4
SAE 6
1/4 NPTF
250 (121)
36 (16)