Pumpe mit hydraulik-umlaufantrieb
Vorschau ausblenden Andere Handbücher für B Serie:
Inhaltsverzeichnis

Werbung

in during the previous stroke is transferred through the outlet
check and discharged to the outlet port. Typical output of the
pump is shown on page 4.
Hydraulic
Fluid Return
to Tank
Hydraulic
Fluid Inlet
Solenoid Valve
(Items 34* & 35)
Pressure Reducing
Valve (Item 38)
Supply inlet hydraulic pressure,
maximum, PSIG (bar) -
Operating working hydraulic
pressure , PSIG (bar) -
Hydraulic Inlet Flow,
GPM (l/min) -
Pump Ratio with manifold -
Operating Temperature, ºF (ºC)-
Grease output at 2 GPM (Fixed)-
*Solenoid valve with manual override standard.
Form 403750
FlowMaster™ Rotary Driven Hydraulic Pump
Illustration 1
3,500 (241)
300 to 450 (20 to 32).
Fixed at 2 GPM.
9:1 at low inlet pressure
(300 to 350 psi [20 to 25
(below 2 gpm [7 lpm])
Pump ratio approaches
11.0:1 ratio at higher
-20 to +150 (-29 to 65)
6 in³/min (at 0°F) to
14 in³/min (at 80°F)

Appropriate Use

dispense lubricants using hydraulic power.
exceeded.
result in loss of claims for warranty and liability.
Flow Control
Valve (Item 39)
Pressure Gauge (Item 32)
Model 85676 only.
Vent
Valve
Solenoid Valve
Illustration 2
Operating Voltage, VDC -
Hydraulic Inlet Port, In -
Tank Return Port, In -
Pump Outlets, In -
Maximum Hydraulic
Fluid Temperature, ºF, (ºC) -
Weight, Lbs (Kg) -
Do not exceed 3,500 PSIG (241 bar) maximum supply inlet
hydraulic pressure. Exceeding the rated pressure may result
in damage to system components and personal injury.
Hydraulic Motor
(Item 42)
Material
Outlet
24VDC Connections
No Connection to
Center Lug
24
SAE 4
SAE 6
1/4 NPTF
250 (121)
36 (16)