Quick start for use with a DMX controller

1
Connect the device to the mains and switch it on. The machine starts to heat up and the display shows
"Warming up".
2
Activate the pump by briefly pressing the WATER PUMP button (button illuminates). The pumping process
takes about 3 minutes, during which time a humming sound is heard.
3
As soon as the heat-up phase is finished (approx. 3 minutes), the display shows "Ready To Fog". After that
the machine is ready to emit fog.
4
Connect the output of your controller to the DMX input of the machine using a DMX cable.
5
Set the DMX start address in the menu using the option "DMX512Add.".
6
When the machine is controlled by a DMX signal, the display shows the set DMX address. DMX control
always has priority over manual operation and the remote control.

Adjusting the DMX start address

To be able to operate the machine with a DMX controller, the DMX starting address must be set. For this, press
the button FUNCTION so many times until "DMX512Add." is indicated in the display. Use the UP and DOWN
buttons to set the address between 001 and 512. You may now start operating the machine via your DMX
controller.

DMX functions

For operation with a controller with DMX512 protocol, the machine is equipped with 1 control channel.
DMX value
0–5
6–255

Making the connections

The unit features 3-pin or 5-pin XLR plugs for DMX connection.
1
Connect the output of your DMX controller to the DMX input DMX IN of the machine with a DMX cable.
2
Connect the DMX output DMX OUT of the machine to the DMX input of the next unit in the chain. Always
connect one output to the input of the next unit until all units are connected.
3
At the last unit, the DMX cable has to be terminated. Plug the terminator with a 120 Ω resistor between Signal
(–) and Signal (+) in the DMX output of the last unit.
4
If the cable length exceeds 300 m or the number of DMX devices is greater than 32, it is recommended to
insert a DMX level amplifier to ensure proper data transmission.
Occupation of the XLR connection: