MALFUNCTIONS
If problems should occur with the use of the stove the cause can possibly be found below. If not,
then you are always welcome to contact your dealer.
The stove is difficult to control – it burns too fast
If the stove is new, then check that the directions have been followed. If the stove is more than
1 year old or if it has been used heavily, then the joints/gaskets may need to be changed. If the
jointings sit for too long the heat makes them lose their ability to keep the stove sealed. If there
is heavy draught in the chimney it may be necessary to fit a damper in it.
The chimney has poor draught after installation
Check that the mounting instructions have been followed. It is especially the conditions sur-
rounding the chimney that may cause problems. Are diameter and length okay, is it sealed, are
smoke pipe and junctions sealed? Is the cleaning hatch sealed? You may need to contact a chim-
ney sweeper to remedy the problem as the chimney may be blocked.
Smoke and soot smell
This can be caused by down-draught in the chimney and most often happens in specific wind
directions. The chimney may be too short for the ridge or trees may have grown and are creating
turbulence.
Remember not to open the door while there are flames.
The stove is difficult to light and may die out
There may be a number of causes. The most typical are:
The damper is not sufficiently open.
The firewood is too wet.
The draught in the chimney is too small or maybe it is blocked or leaking.
The ember layer was too small/incinerated and did not give enough heat to light the logs.
Possibly give some start-up air to the fire by opening the damper (to the right) to get the
stove going again. Then the damper has to be closed again (after max. 10 minutes set it
back to the position between left and the middle).
Depending on the problem it may be necessary to contact the dealer, installer or a chimney
sweeper.
The glass soots up
The wood is too moist.
Lack of draught in the chimney.
Check that the damper is not closed.
Door is closed too early or to late at lighting (lighting and continuous firing, 2).
TECHNICAL SPECIFICATIONS
Nominal heat output:
Height:
Width:
Depth:
Weight ca.:
Average values for testing of TT23 models:
Exhaust gas temperature 247 °C
Exhaust gas mass flow
Efficiency
Flue draught
28
TT23RG
TT23RGS
5,6 kW
5,6 kW
1073mm
1084mm
521mm
531mm
414mm
418mm
126kg
170kg
5.2 g/s
81,0%
11 Pa