Temperature warnings

The temperature in the user module as well as in the computer module of the
DVIVision-USB 2.0-MC4 variant is permanently moitored.
IMPORTANT:
To protect the device from overheating, the video signal of the chan-
nels 2 to 4 is switched off as soon as the temperature reaches the critical value!
Before the temperature reaches the critical value, the user is warned through several
alarm signals:
Alarm level
Action
≥ 70 °C
Blinking Sys-LED at device.
≥ 71 °C
All four monitors of the user module display the image with a blinking frame.
≥ 72 °C
All four monitors of the user module display the image with a fast blinking
frame.
≥ 73 °C
Video channels 2 to 4 are switched off; the monitors 2 to 4 display no image.
The monitor of video channel 1 still displays the image with a fast blinking
frame.