NOTE
Make sure the air conditioning roof unit is centred perfectly. The seal must be
applied continuously around the air conditioning roof unit after being placed
on the roof of the vehicle. This is the only way to ensure a tight seal.
See fig. 8, page 6
➤ Push a hex screw M8 x 110 (4) with a washer 8.4 x 20 (3) through the 4
through holes in the fastening holders (2) and then screw a nut M8 (1)
approx. 50 mm on the hex screw.
➤ Screw the 4 hex screws M8 x 110 in the 4 thread inserts on the bottom of the
unit.
A
NOTICE!
Do not exceed the specified torque under any circumstances. This is necessary
in order to avoid deforming the fastening holder. Ensure that a high amount of
contact pressure is achieved with little expenditure of energy.
➤ Tighten the screws for fastening the unit with a torque of 4 Nm.
➤ Now turn the M8 nuts (1) to tighten them against the fastening holder.
7.6

Installing the electrical supply lines

!
WARNING!
• The electrical power supply may only be performed by qualified personnel
with specialist knowledge.
• Make sure there is no voltage present on electrically operated components
before carrying out work on them!
A
NOTICE!
• Fit a fuse of 25 A to the connection to the vehicle's power supply.
• The battery must be able to supply the required current and voltage
(chapter "Technical data" on page 24).
I
NOTE
The unit is equipped as standard with a 4 m long cable with a cross-section of
2
6 mm
. If longer cable lengths are required, then the cable cross-section must
be increased by an authorised specialist workshop:
In this case cut off the cable as closely as possible to the unit (max. 0.5 m) and
then establish a suitable connection with a larger cable cross-section.
When the cable is extended by 4 m to 6 m in length, the manufacturer
recommends using a cross-section of at least 8 mm
EN
Installation
2
.
17