Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning, Maintenance, Storage And Transport; Disposal And Recycling - Scheppach HC54DC Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Make sure that the connection cable does not hang
on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H05VV-F".
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
.
²
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate
10. Cleaning, maintenance, storage
and transport
m Important!
Pull out the power plug before doing any clean-
ing and maintenance work on the equipment.
Risk of injury from electric shock!
m Important!
Wait until the equipment has cooled down complete-
ly! Risk of burns!
m Important!
Always depressurize the equipment before carry-
ing out any cleaning and maintenance work! Risk
of injury!
10.1 Cleaning
• Keep the equipment free of dirt and dust as far as
possible. Wipe the equipment with a clean cloth or
blow it down with compressed air at low pressure.
• We recommend that you clean the equipment im-
mediately after you use it.
• Clean the equipment regularly with a damp cloth
and some soft soap. Do not use cleaning agents
or solvents; these may be aggressive to the plastic
parts in the equipment. Ensure that no water can
get into the interior of the equipment.
• You must disconnect the hose and any spraying
tools from the compressor before cleaning. Do not
clean the compressor with water, solvents or the
like.
76
GB
10.2 Maintenance work on the pressure vessel
(fig. 3)
m Important! To ensure a long service life of the
pressure vessel (2), drain off the condensed water
by opening the drain valve (1) each time after us-
ing. Release the vessel pressure at the overpressure
valve (15) beforehand. Open the drain screw by turn-
ing counter-clockwise (looking at the screw from the
bottom of the compressor) so that all the condensed
water can run out of the pressure vessel. Then close
the drain screw again (turn it clockwise). Check the
pressure vessel for signs of rust and damage each
time before using. Do not use the compressor with
a damaged or rusty pressure vessel. If you discover
any damage, then please contact the customer ser-
vice workshop.
10.3 Storage
m Important!
Pull out the mains plug and ventilate the equipment
and all connected pneumatic tools. Switch off the
compressor and make sure that it is secured in such
a way that it cannot be started up again by any un-
authorized person.
m Important!
Store the compressor only in a dry location which
is not accessible to unauthorized persons. Always
store upright, never tilted!
10.3.1 Releasing excess pressure
Release the excess pressure by switching off the
compressor and using the compressed air which
is still left in the pressure vessel, e.g. with a com-
pressed air tool running in idle mode or with a blow-
out pistol.
10.4 Transport
The compressor can be tilted it up by means of the
handle so that it can be transported on the wheels.

11. Disposal and recycling

The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic. De-
fective components must be disposed of as special
waste. Ask your dealer or your local council.