4.6. Connect the Charging Station With the Boundary Wire
Once connectors have been prepared to each of the two boundary wire ends then these
can be connected to the charging station as shown below. It is important to lay the wire
from the front of the charging station underneath the base to protect it before connecting
at the rear. This connector should then be connected to the Left hand tab marked S1 or
S2, and the rear boundary wire connector is connected to the Right hand tab marked "+".
S2
S1
S1 or S2
S1
S2
IMPORTANT INFORMATION
Double check that the charger connections are as shown below. Even if it is blue light the
connectors are wrongly connected the machine will not work.
NOTE !
2
When the working area is less than 100 m
or total boundary wire less than 40
m, please connect a 20 Ω / 2 W cement resistance to the boundary wire, or contact the
service.
After connecting the S1 or S2 and "+" connectors to the charging station, the charging
station can be fixed down with the boundary pegs(item 15). Please ensure before this is
done that the charging station is still situated on a flat surface and mains connection is
still can be reached. Also ensure that 2m of straight boundary wire is in front and to rear
of station and any surplus boundary cable is tucked under the charging station base to
protect it.
Once this is done, Connect the charger extension cable (Item 14) to Charging base,
meanwhile ensuring that the power supply is not connected to mains voltage just yet.