2 Safety
A4 = Torsion max. +/- 155°
Maximum load of cable assembly
Fig. 2
Type of voltage
Polarity of the electrodes
Wire types
Type of use
Voltage rating
Protection type of the machine-side
connections
Shielding gas (DIN EN 439)
General torch data according to EN 60 974-7
Tab. 6
Type
®
ABIROB
G350
Product-specific torch data (EN 60 974-7) in connection with iCAT mini
Tab. 7
1For pulse arcs, the load data are reduced by up to 35%.
EN - 8
±
A4:
155°
A5 = Bend max. +90°/-135°
NOTICE
• Torsion A4 and A6 max. ± 355°.
1
Type of
Load
cooling
CO
M21
2
A
A
air
350
300
The load data were determined under standard conditions, at low to medium
heat of reflection, free air circulation and an ambient temperature of approx.
28°C When used under more strenuous conditions, the load data must be
reduced by 10 - 20%.
±
A6:
200°
A5: +90° / -135°
A6 = Torsion max. +/- 200°
®
ABIROB
G350
DC
Usually positive
Commercially available round wires
automatic
Peak value of 141 V
IP3X (EN 60 529)
CO
or M21
2
Duty
Wire-
cycle
mm
%
100
0.8 - 1.2
iCAT mini
Gas flow rate
l/min
approx. 20