Herunterladen Inhalt Inhalt Diese Seite drucken

3M 6000 Serie Bedienungsanleitung Seite 100

Filters
Vorschau ausblenden Andere Handbücher für 6000 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
Note: AX and Reaktor filters are for single use only
The filter should not be used on a second shift even if these maximum usage times are not exceeded. When changing
filters ensure that both filters are replaced simultaneously.
3M™ 6098 AXP3 Filter only
Limitations on the use of these filters may differ from one country to another but in the absence of any limitations in your
country the following should be applied.
a) Low boiling point organic compounds will be divided into four groups.
Group 1
Low boiling point organic vapours with an ES of less than or equal to 10 ppm or which have a short
service life. Check local regulations for ES in your country
Group 2
Low boiling point organic vapours with an ES greater than 10 ppm.
Group 3
Low boiling point organic vapours where protection is provided by filters other than AX (e.g. B, E or K).
Group 4
Low boiling point organic vapours where no or insufficient protection is provided by gas filters
b) Against compounds of groups 1 and 2, AX filters complying with AS/NZS 1716 can be used up to the maximum
concentrations shown in the table below or 100 x Workplace Exposure Standard, whichever is lower.
Group
Max Concentration (ppm)
Group 1
100 ppm
Group 2
500 ppm
Group 3
1000 ppm
Group 4
5000 ppm
c) Only new, unused filters from their original packaging should be fitted to your facepiece. During one 8 hour shift,
repeated use of an AX filter is permitted, provided the maximum usage time shown in the table above is not exceeded.
d) Use of AX filters against mixtures of low boiling point organic compounds or mixtures of low boiling point organic
compounds and other compounds is not permitted as one or more of these compounds may be desorbed.
e) AX filters may be used as A2 filters ONLY if no other low boiling point organic compound is present. A1 or A2 filters are
not to be used against low boiling point organic compounds.
Group 1
Acetaldehyde
Bromomethane
1,3-Butadiene
3-Chloro-1-propene (Check
local regulations)
Diethyl Amine
Dimethyl ether
1,1-Dimethylethylamine
Ethanethiol
Iodomethane
Methyl Alcohol
Propyleneimine
Vinyl Chloride
Propanal
2-Propenal (acrolein)
1,1-Dichloroethene
APPROVALS
These products are type approved and audited annually by BSI, Kitemark Court, Davy Avenue, Knowlhill, Milton Keynes
MK5 8PP, UK, Notified Body No. 0086. They meet standard AS/NZS 1716:2012, Respiratory protective devices – gas
filter(s) and combined Filter(s). These products are CE Marked to the requirements of Community Directive 89/686/EEC
or European Regulation (EU) 2016/425. The applicable legislation can be determined by reviewing the Certificate and
Declaration of Conformity at www.3m.com/Respiratory/certs. These respirators have been producted to comply with the
requirements of the Australian Standard AS/NZS1716:2012 under an agreed production certification scheme operated
during manufacturing in accordance with the SAI Global Standards Mark.
Group 2
Group 3
n-Pentane
Carbon disulphide
Acetone
Carbonyl Fluoride
Bromomethane
Dimethylamine
Butane
Ethylamine
Chloroethane
Formaldehyde
Methanethiol
Cyclopentadiene
Dibromodifluoromethane
2-Propanethiol
Diethyl ether
Trichlorosilane
Dimethyloxymethane
Trimethyl amine
Ethylformate
Methylacetate
Methyl propane
100
Max Usage Time (mins)
40 mins
20 mins
60 mins
20 mins
Group 4
1,2-Dichloro-1,1,2,2-tetrafluoroethane
Diazomethane
1,1-Dimethylhydrazine
Bromotrifluoromethane
Chlorodifluoromethane
Chloromethane
Dichlorodifluoromethane
Dichlorofluoromethane
1,1-Difluoroethane
Ketene
Methyl acetylene
Propane
Trichlorofluoromethane
1,1,2,Trichloro -1,2,2 trifluoroethane
Ethylene Oxide

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

609160926095609660986099

Inhaltsverzeichnis