Herunterladen Inhalt Inhalt Diese Seite drucken

Construction Specifications; Conformity To International Standards; Electromagnetic Compatibility (Cem) - Chauvin Arnoux AmpFlex A110 Bedienungsanleitung

Flexible ac- stromwandler
Vorschau ausblenden Andere Handbücher für AmpFlex A110:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 46

3.8. CONSTRUCTION SPECIFICATIONS

Coil
Length (mm)
Clamping diameter (mm)
Shielded lead 4 mm in diameter between the sensor and the electronic unit:
„ A110: 2 metres long
„ A130: 3 metres long
Electronic unit:
„ Overall dimensions: 120 x 58 x 36 mm
„ A110: Output by a cable 50 cm long and 2 plugs 4 mm in diameter.
„ A130: Output by a cable 50 cm long and 3 BNC connectors.
Mass of the device:
„ A110: approximately 360, 450, and 500 g, depending on the size of the sensor.
„ A130: approximately 1 kg.
Protection index:
IP 54 for the electronic unit and IP 67 for the flexible sensor per IEC 60529.
The flexible coil stands up well to oils and aliphatic hydrocarbons.

3.9. CONFORMITY TO INTERNATIONAL STANDARDS

Electrical safety per IEC 61010‑2‑032 for type B sensors.
Single-phase electronic unit
and connecting cable to the
measuring instrument
Double insulation
Measurement category: IV
Rated voltage: 600V
(1): or 1000 V in category III.
The 250 V mains adapter (option).

3.10. ELECTROMAGNETIC COMPATIBILITY (CEM)

Emissions and immunity in an industrial environment per IEC 61326‑1.
450
120
Three-phase electronic unit
and connecting cable to the
measuring instrument
Double insulation
Measurement category: III
Rated voltage: 600 V
(1)
800
1200
235
360
40
Sensor
and connecting cable to the
electronic unit
Double insulation
Measurement category: IV
Rated voltage: 1000 V

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis