Error codes of the device Err 1 and Err 2
Technical data - trigger level
Comparator input
Inputs
Input level
Input level Low
Input level High
Input resistance
6.1

Dimensions

96
109
6.2

Default setting

The device is supllied programmed with the following default
parameters:
Measurement function
Signal type at F1
Input logic
Scale F1, F2, F3
Display update
Time-out
Time unit F1, F2
Decimal point F1, F2, F3
Assignment of basic display
Program protection code
6.3

Error indications

Err 6
999999
flashes
www.baumerivo.com
Input circuit
PNP- / NPN-logic
Programmable
0...2 VDC
3...40 VDC
3 kΩ
124
20
ratio F1:F2
one track (up/down)
PNP
1.0000
every 1 second
1 second
rpm
no decimal point
no reset after 15 seconds
no code set
Hardware error, must be sent in for repair.
Input frequency at tachometer F1 is too high. The
error can be cancelled by pressing the
Over-range of displays F1, F2, F3. Can also occur
at low frequencies due to unfavourable parame-
ter setting.
For example:
F1 = 100 Hz, bF1 = 0.01, unit = 1/h
100/0.01 * 3600 = 3600 000
Flashing of the numbers 999999 is automatically
cleared after correcting the parameter or reducing
the frequency.