Herunterladen Diese Seite drucken

Baumer TA201 Betriebsanleitung Seite 29

Elektronischer tachometer

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Modifying the number ➜ Enter the respective number using the keys
Switching back ➜ Hold down the key
Line 21
Line 22
Line 23
Line 24
Line 25
Line 26
Programming field 3
Programming field three begins with line 21. In this programming
field the programming lines are displayed in sequence.
The default setting is always marked with a *.
The programming lines are selected in sequence. The input is
stored when you use the
gramming to the operating mode.
Press the key
Measurement functions (Display at F3)
0 * Ratio F1:F2
1
Difference between F1 - F2 (with sign)
2
Extension/compression (with sign)
3
Throughput time of a defined path
4
Time measurement via start and stop signal
5
Time measurement of period duration
6
Time measurement of pulse duration
7
Pulse rate measurement
Measurement function 0, 1 and 2
0 * Measurement function as in line 21
1
F1 - F2 inverted
F1 signal type and max. frequency of F2
0 * F1 Track A possibly with up/down F2 40 kHz
1
F1 Track A 90° track B
2
F1: Track A possibly with up/down F2: 25 Hz (contact selection)
3
F1: Track A 90° track B
Input logic / switching voltage of signal inputs
0 * PNP , switching voltage at appr. 11 V
1
NPN, switching voltage at appr. 11 V
2
PNP , switching voltage at appr. 5 V, or Namur with 8 V ext. supply
3
NPN, swit. voltage at appr. 5 V, or Namur without intrinsic safet
4
PNP , switching voltage at appr. 2.5 V
5
NPN, switching voltage at appr. 2.5 V
Scale F1 (divider), at speed measurement:
* 1,0000
0,0001...9999,99
Scale F2 (divider), at rpm measurement:
* 1,0000
0,0001...9999,99
www.baumerivo.com
key to switch back from the pro-
again, for fast run-through hold the key down.
and press the key
F2 40 kHz
F2: 25 Hz (contact selection)
TA201
and
.
again.
pulses/rev.
circumf.
pulses/rev.
29