Herunterladen Inhalt Inhalt Diese Seite drucken

Checking The Mounted System; Disposal Of The Window Unit; Maintenance - GEZE ECchain 230 V AC Anschlussplan

Vorschau ausblenden Andere Handbücher für ECchain 230 V AC:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
ECchain
2.6

Checking the mounted system

à The measures for security and prevention of crushing, impact, shearing
or drawing-in spots, in particular at danger areas of less than 2.5 m
height are to be carried out and checked.
A measure is for example the use of a switch with default off (e.g. GEZE
fan switch LTA-LSA Mat. No. 118476). A key switch with default off must
be used (e.g. GEZE Mat. No. 117996 for SCT, 090176 for cylinder) in places
where there are children or people with limited ability to judge.
After the installation has been completed, check that the system is set
X
correctly and functions correctly and safely.
Check all the functions by means of a trial run.
X
à The end user has to be instructed in all the important operating and
handling steps after completion.
3

Disposal of the window unit

The window unit consists of materials that have to be recycled. The indivi-
dual components have to be sorted in accordance withtheir material type.
à Aluminium (profiles)
à Iron (screws, chain, ...)
à Plastic
à Electronic components (motor, controller, transformer, relay, ...)
à Cables
Dispose of the parts in accordance with the statutory regulations.
X
4

Maintenance

GEZE prescribes regular maintenance (at least once a year). This is to be car-
ried out by a suitably qualified person. In the process thefunction as well as
the state of the mechanical equipment (imbalance or signs of wear, damage
to fastening parts) and the electrical connections are to be checked. The
system may not be used during repair and setting work.
Before working on the electrical system interrupt the power supply
X
(mains and battery) and verify the safe isolation from supply.
Inspect the fixations and clamping screws for firm seating.
X
Clean dirt and dust from the drive during maintenance.
X
Attention: the window closes automatically!
Danger of crushing and clamping!
Before assembly read enclosed safety instruction and carry out
during assembly and drive operation! Warranty claims presuppose
professional assembly, installation and maintenance according to the
guidelines of the manufacturer.
Hand over this wiring diagram to the electrician for information.
X
Disposal of the window unit
EN 7