9 Maintenance and cleaning

Regular and lasting maintenance and cleaning are the prerequisite of a long life and a trouble-free function.
In doing so, observe the following:
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair work, the following instructions
must be adhered to:
• Switch off the power supply.
• Cut off the compressed air supply.
• Pull the mains plug.

Electric shock

Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation.
• Replace any damaged, deformed or worn parts.
NOTE
• The maintenance intervals given are recommended values and refer to single-shift operation.
• Maintenance and cleaning work may only be carried out by qualified and trained specialists.
• Always wear your personal protective clothing when performing maintenance and cleaning work.
The cleaning station BRS-LCi is virtually maintenance-free. However, it is necessary to regularly clean and
evaluate the mechanically stressed parts in order to maintain its value and to guarantee its full ability to
function.
9.1 Weekly cleaning
1 Check the condition of the milling cutter.
2 Clean the clamping unit or the milling cutter.
9.2 Monthly cleaning
A monthly basic cleaning is recommended, and necessary in case of extreme working conditions.
10 Troubleshooting
NOTE
• Some problems are listed below, with descriptions of possible causes and solutions. If the measures
• Please also consult the operating instructions for the welding components, such as power supply,
Fault
Cause
Compressed-air
• Compressed-air supply / hose connection
interrupted
motor does not run
• Valve actuator does not move
Insufficient cleaning • Milling cutter defective or blunt
Tab. 11
Troubleshooting
DANGER
DANGER
described below are not successful, please consult your dealer or the manufacturer.
compressed air line.
9 Maintenance and cleaning
Solution
• Check all supply lines leading to the cylinder and
the screwings
• Motor defective; replace
• Replace way valve
• Replace milling cutter