48
4
2
3
1
(8)
(9)
(10)
Secure cable of the "State 112 KIT" (7)
6
and the AC cable (8) to the power sta-
ge set (9) again using 4 screws 5x10
TX25 (10) [3.5 Nm]
Blue cable of the KIT and AC line with
7
number 4 at position 4
Any black cable of the KIT and AC line
8
(7)
with number 3 at position 3
Any black cable of the KIT and AC line
9
with number 2 at position 2
Any black cable of the KIT and AC line
10
with number 1 at position 1
Screw order:
-
Screw 5x10 TX25
-
Cable lug of the State 112 KIT
-
Cable lug of the AC line
-
PC board
Close the inverter and place it in the
11
mounting bracket (see "Opening and
closing the device")
WARNING! Observe the positions
of the cables as well as the screw
order!