Herunterladen Diese Seite drucken

Indesit p 604 Installation Und Gebrauch Seite 8

Einbau-kochmulden

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27
Installation instructions for built-in stove tops
The following instructions are directed at the qualified
installer so that the installation and maintenance
proceedures may be followed in the most professional and
expert manner possible.
Important: Unplug the electrical connection before
performing any maintenance or regulation upkeep
work.
Installation of built-in stove tops
The electric hobs are prepared with protection degree
against excessive heating of Y type, it is therefore possible
to instal them next to furniture which is higher than the
working board. For a correct installation of the cooking
top the following precautions must be followed:
a) The hoods must be installed according to the
requirements in the hood handbook.
b) The dimensions of the cutout for the appliance must
be those indicated in the figure. Clamps are provided
to fasten the cooktop to counters measuring from 20
to 40 mm in thickness. To fasten the cooktop securely,
it is recommended that all the clamps be used.
Fastening Clamps - Assembly Diagram
Clamp Position for
H=20mm top
Clamp Position for
H=40mm top
N.B: Use the clamps contained in the "accessory kit."
555 mm.
Clamp Position for
H=30mm top
Front
Back
c) In case a wooden panel should be fitted under the top
for insulation, it will have be fitted at a minimum distance
of 20 mm from the inferior part of the top.
Important: When installing the hob on a built-in oven, the
oven should be placed on two wooden strips; in the case
of a joining cabinet surface, remember to leave a space
of at least 45 x 560 mm at the back.
When installing on a built-in oven without forced ventilation,
ensure that there are air inlets and outlets for ventilating
the interior of the cabinet adequately. Assembly examples
are given in figs.
Electric connections
The electric hobs are supplied without power supply cable
since the cable must be sized according to the type of
electrical connection used (see attached connection
diagram). Follow these steps to connect the cable:
Open the terminal board box by unscrewing the 3
screws and remove the lid.
Connect the wires as shown in the diagram below.
400 3N
H05RR-F 5x1.5 CEI-UNEL 35363
400V 2N
H05RR-F 4x1.5 CEI-UNEL 35363
230V 1N
H07RN-F 3x2.5 CEI-UNEL 35364
Fix the cable with the cable hitch, shut the lid and and
screw down with the 3 screws.
8
1
2
3
4
5
N
T
S
1
2
4
5
3
R
N
S
1
2
3
4
5
N
R
R

Werbung