6.3 Power connections

Connection
C1
D1
U1
V1
U2
V2
C2
D2
WARNING
Hazardous voltages can appear at the outer surfaces of unearthed converters.
Such voltages can result in death, severe injury or considerable damage to
property.
If the converter (plug-in or built-in unit) is installed in such a manner that it is
not earthed, an earth conductor must be connected to the chassis or housing in
order to afford protection to the operating personnel. The motor frame and the
transformer housing (where employed) must likewise be earthed. The specific
requirements regarding equipment earthing shall be taken from the appropriate
safety regulations (e.g. DIN, VDE) and from all other relevant government and
local standards.
Siemens AG ATD TD 6
Function
+ Output of converter
– Output of converter
AC connections of power section and electronics section
With 2AC400V:
jumper E1-E2
With 2AC230V:
jumper E2-E3
AC connections of field rectifier
+ Output field rectifier
– Output field rectifier
Operating Instructions 6RX1220-0DD74
6RA22
-8DD21-
- 49 -