4. TECHNICAL CHARACTERISTICS.
Power supply voltage
Frequency
Max. rated pump current
Max.operating pressure
Range of start pressure (on/off mode)
Max. stop pressure (pressure dependent mode)
Max. start pressure (pressure dependent mode)
Enclousure
Max. water temperature
Max. ambient temperature
Max. flow
DN inlet port
DN outlet port
Net weight
5
. HYDRAULIC CONNECTION.
Check automatic control unit for transportation damage upon receipt.
Before hydraulically connecting the pump, it is essential to install a non-return valve at the pump´s suction side.
Cervomatic EDP.2 must be connected in vertical position with the inlet port ( 1 ¼" male) directly connected to the main pump
discharge, and the outlet port (1 ¼" male) to the main network.
Thread the accumulator tank to the back cover using an adequate sealing material.
Cervomatic EDP.2 has an integrated accumulator so that it is not necessary to install an external one. However, if frequent flow
consumptions are planned, it is recommended to operate in pressure-dependent mode, and to install an external accumulator.
6. ELECTRIC CONNECTION.
The unit should be disconnected from the electric supply before performing any work inside the unit.
Wrong connections may destroy the control electronics.
Table 1. Required cable dimensions
~1x230 VAC
Power supply voltage
H07RN-F 3G1,5
Motor supply
H07RN-F 3G1,5
Use H07RN-F type cables of sections sufficient for the applicable power supply as given in Table 1.
Check power supply. Remove the cover of the control electronics and establish the connections according to the indications
located on the connection strip base.
Pumps with three-phase motors:
Power supply of control unit: connect L1, L2, L3 via a three pole motor protection switch (recommended) in OFF mode
and ensure proper connecting PE.
Motor: connect motor to U, V, W and PE (earth).
Pumps with single-phase motor:
Power supply of control unit: connect L1 and L2 via a motor protection switch (recommended) in OFF mode and ensure proper
earthing by connecting PE.
Motor: connect motor to U, V and PE (earth).
The earth conductor must be longer than the others. It is the first one to to be connected during installation, and the last one to be
disconnected during dismantling.
Connect all auxiliary devices:
Alert monitoring: Cervomatic EDP.2 has a volt-free contact with 1 A maximum intensity for the transmission of signals to diferent
types of alarm equipment (optical, acoustic, etc) when a failure, which was previously displayed in the LCD screen, is
detected. For connection, see Fig. 4.
Min. level control: there is an input for stopping all the pumps as soon as the external switch for minimum level detection trips. For
connection see Fig. 4.
For the voltage selection set the selector:
to A for 220-240 V.
to B for 380-415 V.
When closing the cover after electrical connection, ensure
correct position of the cover seal. Make sure that internal
wires are not clamped between the cover parts.
Check rotational direction of the pump before
commissioning.
7
Downloaded from
www.Manualslib.com
~1x230 / ~3x230 / ~3x400 VAC
50/60 Hz
16(10)
A
10 bars
1 ÷ 5 bar
7 bar
6,5 bar
IP55
40ºC
50ºC
15.000 l/h
G1 ¼" male ISO 228
G1 ¼" male ISO 228
3,3 kg
~3x230 VAC
H07RN-F 4G1,5
H07RN-F 4G1,5
LATERAL CONNECTION.
1. Pump.
2. Power supply.
3. Minimum level (optional).
1
3
2
Fig 2. Lateral connection.
manuals search engine
EN
E
N
7. ACCUMULATOR PRESSURE.
The accumulator is pre-pressurised in the factory at 3,5 bars. It should be pressurised 0,2 bar below the configured start pressure of the
pump in pressure-dependent mode. If accumulator is not sufficiently pressurised: in MANUAL MODE open a tap and, using a bicycle pump
and adapter, pressurise the tank through the valve. Put the cap back on the valve. Push AUTO On/off.
8. STARTUP.
It is recommended to connect Cervomatic EDP.2 to the electric supply via the motor protection switch. Wait for 5 seconds while the
Cervomatic EDP.2 is running autotest.
If the unit is started for the first time, it will directly open the configuration menu. The LCD screen will display a message for language selection.
Choose your language and start the configuration procedure - see 7. CONFIGURATION.
Once the unit is configured, switch to manual mode by pressing the AUTO On/Off push-button (green LED off). Verify the rotational direction
of the pump, and whether it is correctly primed using the Start/Stop push-button.
Press AUTO On/off. The unit is ready to operate.
9. CONFIGURATION.
Values may be changed by using
press MENU. Each time ENTER is pressed, the different screens, which display the sequence of configuration, will open
automatically.
0
PLINE
PON
03,0 bar 02,0 bar
1
Cervomatic EDP.2
V 0.0
2
LANGUAGE
ENGLISH
3
INT. MAX.
~3x400 VAC
OFF
H07RN-F 4G1,5
4
H07RN-F 4G1,5
LEVEL PROBE
NOT
(1)
5
OPERATING MODE
ON-OFF
(2)
P ON
6
05,0 bar
7
8
START DELAY
00 sec
9
STOP DELAY
00 sec
10
PLINE
PON
05,0
03,0
PLINE INT
05,0
9,0
(1) "
P ON" must be at least 0.2 bar higher than manometric pressure.
Eg: with 20 meters of water column
The pump must be able to supply at least 0.5 bar more than "P ON".
(2) Being in pressure dependent mode "P OFF" must be at least 0.5 bar lower than the pressure supplied by the pump.
, changes can be saved by pressing ENTER. If you wish to quit the configuration sequence,
Push MENU for 3 seconds
to start configuration sequence
This temporary message gives information about the software version
Choose language using the
ENGLISH", "LANGUE FRANÇAISE", "LINGUA ITALIANA" and "IDIOMA ESPAÑOL".
The rated current intensity - from 0 to 10 A - is entered by means of the
enable thermal protection of the motor. This value is given on the name plate of the
motor. Press ENTER to confirm.
If there is no external device for detecting the minimum water level, press ENTER to
confirm. Otherwise, change NO for YES
In this step, the mode of operation can be selected using
OPERATING MODE
On-off mode: only the start pressure is configured. The pump will start at this
PRESSOSTATIC
pressure - with the delay configured in the next step - and it will stop when there is
no flow demand.
Pressure-dependent mode: the start and stop pressures of the pump can be
configured.
This is the start pressure for the pump. The desired pressure values within the respective
P ON
range can be chosen using the
05,0 bar
On-off mode: from 1 to 5 bars.
Pressure-dependent mode: from 0 to 6,5 bar.
This is the stop pressure for the pump in pressure-dependent mode. It must be within a
P OFF
range of
1 to 7 bar and 1 bar above the start pressure.
06,0 bar
Use
to modify the values.
This is the delay to start the pump once it has reached the start pressure. Choose the
desired timing using the
keys.
This is the delay to stop the pump once it has reached the stop pressure. Choose the
desired timing using the
keys.
System is ready to operate.
PLINE PON POFF
Press AUTOMATIC On/Off, green LED is lit.
05,0
02,0 06,0
From this moment the LCD screen will show:
On-off mode: current pressure (PLINE) and start pressure (PON).
F
1
Pressure-dependent mode: current pressure (PLINE), start pressure (PON) and
stop pressure (POFF).
Using
in AUTOMATIC mode, it is possible to access a detailed expert screen with the
following parameters:
P line: current pressure.
INT: present current consumption.
F: position of the flow sensor (0: no flow, 1: with flow)
P ON > 2.2 bar.
EN
E
N
.
MENU
MENU
3"
3"
ENTER
keys: PRACHE DEUTSCHE", "LANGUAGE
MENU
ENTER
keys to
ENTER
MENU
ENTER
MENU
using the
keys
.
. There are 2 options:
ENTER
MENU
keys
:
ENTER
MENU
ENTER
MENU
ENTER
MENU
ENTER
MENU
On
MENU
Off
8

Werbung

loading