Clear Tip Clog
In the event that particles or debris clog the spray tip, this
sprayer is designed with a reversible spray tip that quickly
and easily clears the particles without disassembling the
sprayer.
To avoid serious injury, never point gun at your hand or
into a rag.
1. Engage trigger lock. Rotate spray tip to unclog position.
Disengage trigger lock. Trigger gun at waste area to clear
clog.
Unclog:
NOTE: If spray tip is difficult to rotate when turning to
the unclog position, perform Pressure Relief Procedure
then turn Prime/Spray valve to spray position and repeat
step 1.
2. Engage trigger lock. Rotate spray tip back to spray
position. Disengage trigger lock and continue spraying.
Cleanup
Flush gun after each work shift and store in a dry locati-
on. Do not leave the gun or any parts in water or cleaning
solvents.