a. Use spray tip to align gasket and seal in the tip guard.
b. Spray tip must be pushed all the way into the tip guard.
Turn spray tip to push down.
c. Turn the arrow shaped handle on the spray tip forward
to the spray position.
4. Screw spray tip and tip guard assembly onto the gun
and tighten.
Aligning Spray
1. Perform Pressure Relief Procedure.
2. Loosen tip guard retaining nut.
3. Align tip guard horizontally to spray a horizontal pat-
tern.
4. Align tip guard vertically to spray a vertical pattern.
Horizontal
Spraying
1. Unlock trigger lock.
2. Be sure the arrow shaped tip faces forward (spray).
3. Hold gun perpendicular and approximately 12-inches
(30 cm) from surface. Move gun first, then pull gun trig-
ger to spray a test pattern.
4. Slowly increase pump pressure until coverage is uni-
form and even (see sprayer instruction manual for additio-
nal information).
5. Periodically inspect gun handle vent for fluid buildup,
this could indicate an internal leak. Service fluid tube and
o-ring as necessary.
Vertical
197
Leakage opening