Installation

The installation should be done in the following order:
 Switch off power and mark clearly that this elevator is
out of service.
 Installation of the IMS 100 Pro .
 Electrical installation and integration of IMS 100 Pro.
 Power-up and test for proper function.
5.1

Switch OFF main power

For your own safety, turn the power off before you start
working on the elevator! Clearly mark that this elevator is
out of service. Keep the working area closed to the public
all the times.
5.2

Possible sensor positions

IMPORTANT
for a correct installation
 Cable exits right facing into the elevator cabin
(Figure 2, Figure 3, Figure 4)
 Arrow on product label shall point from inside to
Neu
the outside of the cabin.
CEDES PN: 114 574
Made in
IMS 100 PRO
Switzerland
CH-7302
Lot 200529/550806/000353/006061
Landquart
HW: 2.00 / SW: 2.00
Voltage: 19.2 ... 28.8VDC
Output: 120 mA
IP65
CSA B44.1 ASME A17.5

1. Center opening door

The sensor is placed in the door frame in the center of the
door opening; see chapter 5.3.1 and 5.3.2 for details.
Cabin
Light curtain
Figure 2:
Mounting position - center opening door
2. Right side-opening door
The sensor is placed in the door frame. A minimum distance
from the slam post must be kept; see chapter 5.4.1 and
5.4.2 for details.
IMS 100 Pro
(observe cable direction - right side)
Cabin
Light curtain
Figure 3:
Mounting position - right side-opening door
© CEDES | V 4.0
CAUTION:
DO NOT OPEN!
LASER CLASS 4 INSIDE
20190716_IMS_Prod_Label.pptx
IMS 100 Pro
(observe cable direction)
Protection area
Protection area
3. Left side-opening door
The sensor is placed in the door frame. A minimum distance
from the slam post must be kept; see chapter 5.5.1 and
5.5.2 for details.
(observe cable direction)
Cabin
Light curtain
Figure 4:
Mounting position - left side-opening door
5.3
Center opening door
5.3.1 Surface mounting
Figure 5:
Surface mounting (center opening doors)
The sensor has to be installed on the transom:
Distance:
≥ 22 mm ≤ 100 mm
Figure 6:
Position of the mounting box on the transom (center
opening doors)
English
IMS 100 Pro
Protection area
Mounting box
Self tapping screws
Preassembled sensor
Expanding rivets
Position of mounting box
Transom
5