Trouble shooting

Problem
Action
No function, door open ` Check power supply.
` Check wire (connection to power 24 VDC).
` Check function of the Power Line Converter.
Door constantly open
` Check electrical connection of the light curtain and IMS 100 Pro.
` Check alignment of IMS 100 Pro (check cable direction, see Figure 2 to Figure 4).
` Check electrical connection to the relay (COM, NO, NC) of the Power Line Converter.
No person or object
` Check that the white wire is connected to either 24 VDC or GND (0 V).
moving in the IMS 100
` Check mounting position (see Chapter 5 ).
Pro detection area
` Check the optical influence of IMS 100 Pro to the light curtain.
` Clean the sensor and the optical cover.
` Make sure that the cables and sensor are located away from sources of electromagnetic
Door closing although
` Check electrical connection of the light curtain and IMS 100 Pro.
person or object in the
` Check that the white wire is connected to either 24 VDC or GND (0 V).
IMS 100 Pro detection
` Check electrical connection to the relay (COM, NO, NC) of the Power Line Converter.
area
` Check alignment of IMS 100 Pro (check cable direction, see Figure 2 to Figure 4).
` Check mounting position (see Chapter 5 ).
` Clean the sensor and the optical cover.
` Make sure that the cables and sensor are located away from sources of electromagnetic
Random door
` Check influence of other infrared emitting sensors / devices.
openings
` Clean the sensor and optical cover.
` Make sure that the cables and sensor are located away from sources of electromagnetic
` Check for breaks in the cables by feeling the cables by hand.
` Avoid interference from blinking lights or infrared light sources such as photo cells or other optical
` Check current supply from the used power supply (> 250 mA)
If a problem persists, please contact your local CEDES representative. Visit www.cedes.com for contact data.

10. Maintenance

Although the IMS 100 Pro does not need regular maintenance, a periodic functional check is strongly recommended:
 Make sure the optical cover is clear of dirt and dust. If necessary, clean the cover with a soft towel.
 Check the mounting position, cable routing and connection of the sensor.
NOTICE
Damage to the optical elements
 Never use any solvents, cleaners or mechanically abrasive towels or high-pressure water to clean the sensor.
 Avoid scratching the optical covers while cleaning.

11. Disposal

The IMS 100 Pro should only be replaced if a similar protection device is installed. Disposal should be done using the
most up-to-date recycling technology according to local regulations and laws. There are no harmful materials used in the
design and manufacture of the sensor. Traces of such dangerous materials may be found in the electronic components
but not in quantities that are harmful.
Waste Electrical and Electronic Equipment (WEEE):
At the end of life, this equipment should be collected separately from any unsorted municipal waste.
12
interference.
interference.
interference.
sensors.
English
© CEDES | V 4.0

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis