8. Dismounting, return ... / 9. Specifications
8.3 Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an
environmentally compatible way and in accordance with the country-
EN
specific waste disposal regulations.
9. Specifications
General data
Measurement accuracy
Minimum distance from
the glass tip to an opposite
surface
Mounting position
Insertion length IL
Process connection
Surface
18
Downloaded from
www.Manualslib.com
manuals search engine
±0.5 mm
≥ 10 mm
as required
min. 30 mm
Standard length 30, 50, 100, 150, 200,
250, 300 mm
other lengths on request
Clamp connections to DIN 32676
■
- DN 10 ... DN 50 row A
- DN 21.3 ... DN 48.3 row B
- DN ¾" ... DN 2" row C
Clamp connections to ISO 2852
■
(DN 17.2 ... DN 51)
Tri-clamp (DN ¾" ... DN 2")
■
R
< 0.8 μm
a
WIKA operating instructions model OLS-F1