Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications - WIKA RLS-7000 Betriebsanleitung

Oem-schwimmerschalter, miniaturausführung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9. Specifications

9. Specifications
Specifications
EN
Switching
power
Accuracy
Permissible
temperatures
Medium
Ambient
Storage
Operating
pressure
Density
For further specifications see WIKA data sheets LM 50.11, LM 50.12 and
the order documentation.
20
AC 230 V; 100 VA; 1 A; max. 100 Hz
DC 230 V; 50 W; 0.5 A
≤ 3 mm switch point accuracy incl. hysteresis, non-repeatability
Polypropylene (PP):
-25 ... +80 °C [-13 ... +176 °F]
-25 ... +80 °C [-13 ... +176 °F]
-25 ... +80 °C [-13 ... +158 °F]
≤ 4 bar [≤ 58.0 psi]
Polypropylene (PP):
≥ 700 kg/m³ [43.7 lbs/ft³]
WIKA operating instructions models RLS-7000, RLS-8000
Polyamide PA6.6:
-25 ... +100 °C [-13 ... +212 °F]
-25 ... +100 °C [-13 ... +212 °F]
-25 ... +80 °C [-13 ... +158 °F]
Polyamide PA6.6:
≥ 750 kg/m³ [46.8 lbs/ft³]