7. Initial start-up and operation
Specifications
Permissible temperature of
Medium
■
Ambience
■
Storage
■
Rated temperature range
Temperature coefficients within
rated temperature range
(active compensated)
Mean TC of zero
■
Mean TC of range
■
RoHS-conformity
CE- conformitiy
Pressure equipment directive
■
EMC directive
■
Assembly and packing area
Packaging
Shock resistance
Vibration resistane
Wiring protection
Short-circuit proofness
■
Reverse polarity protection
■
Weight
When designing your plant, take into account that the stated values (e.g.burst pressure, over pressure safety)
apply depending on the material, thread and sealing element used.
Operating instructions/Betriebsanleitung, WUD-2x
Downloaded from
www.Manualslib.com
Models WUD-20, WUD-25 and WUD-26
-20 ... +100 °C / -4 ... +212 °F
-10 ... +60 °C / 14 ... 140 °F
-10 ... +60 °C / 14 ... 140 °F
-20 ... +80 °C / -4 ... +176 °F (active compensated)
≤ 0.10 % of span / 10 K
≤ 0.15 % of span / 10 K
Yes
97/23/EC
2004/108/EC, EN 61 326 Emission (Group 1, Class B) and Immunity (industrial locations)
Clean room class 5 according to ISO 14644
Double bagging according to SEMI E49.6
40 g SEMI F69-0302/MIL-STD 810 Part 2, 500 g labory test method 516.5, procedure 1, sawtooth shock
MIL-STD 812 Part 2, labory test method 514.5, procedure 1, category 4
S
towards U -
+
U
towards U-
+
Approx. 0.2 kg
manuals search engine
GB
13