7. Initial start-up and operation
Wiring details
Bayonet connector, 4-pin
3-wire
U+ = A
Switching outputs
Wire gauge
-
Diameter of cable
-
Ingress protection
IP 67
per IEC 60529
The ingress protection classes specified only apply while the pressure transmitter is connected with female connectors
that provide the corresponding ingress protection.
Wiring details
Sub-D HD connector, 15-pin
3-wire
U+ = 7
Switching outputs
SP1 = 14, SP2 = 13
Wire gauge
-
Diameter of cable
-
Ingress protection
IP 20
per IEC 60529
The ingress protection classes specified only apply while the pressure transmitter is connected with female connectors
that provide the corresponding ingress protection.
10
Downloaded from
www.Manualslib.com
Circular connector M12x1,
4-pin
U- = D
S+ = B
U+ = 1
SP1 = 2
-
-
IP 67
U- = 5
S+ = 2
U- = 12
manuals search engine
Circular connector M12x1,
5-pin
4
3
2
1
U- = 3
S+ = 4
U+ = 1
U- = 3
SP1 = 2, SP2 = 5
-
-
IP 67
Operating instructions/Betriebsanleitung, WUD-2x
Flying leads, 1.5 m or 3 m
S+ = 4
U+ = red U- = black S+ = brown
SP1 = blue, SP2 = white
2
0.22 mm
(AWG 24)
4.8 mm
IP 65
GB