Testing / Repair
Testing / Repair
 Regulary check the pump according to the relevant national
 Repairs should only be carried out by the manufacturer
Note
 Depressurise the system.
 Always replace defective parts.
 There must be at least 6 balls in the swivel joint.
Replacement of hose connector and / or seal:
1. Take off the safety lever (screw out safety screw)
2. Take out the balls off the swivel joint (maybe with the help of a
Downloaded from
www.Manualslib.com
safety instruction and/or rules for prevention of accidents
(in Germany these are e.g. BGV A3).
or an authorized repair shop.
Separate pump from current.
Empty hose and hand nozzle.
Only use genuine spare parts.
magnet pin)
manuals search engine
Ball
Seal
Safety lever
Hose connector
Safety screw
18