Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Assembly
Important! The fitting must be installed, flushed
and tested after the valid norms.
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the basin / bidet.
3. Slip the fixation piece including the washer over
the threaded pins and tighten the nuts.
4. Connect the connecting hose / supply pipes to
the isolation valves;
cold right - hot left.
5. 1 0 0 0 6 0 0 0 , 1 0 1 1 1 0 0 0 , 1 0 1 1 6 0 0 0 ,
10211000:Connect the pull rod to the pop-up
waste.
The hot and cold supplies must be of equal pressures.
Technical Data
This mixer series-produced with water-
dimmer
(flow limiter)
®
Rate of flow with waterdimmer:
Rate of flow without waterdimmer: 14 l/min 0.3 MPa
Operating pressure:
Recommended operating pressure: 0.1 - 0.5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temperature: 65° C

Operation

open
10
English
Hansgrohe single lever mixers can be used toge-
ther with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0.15 MPa.
If the continuous water heater causes any problems
or there is not enough flow of water, the waterdimmer
(5a) located behind the aerator must be removed.
Spare parts (see page 3)
1
2
3
4
5
6
7
8
9
10 supply pipe
Special accessories
7 l/min 0.3 MPa
X
max. 1 MPa
1,6 MPa
max. 80° C
close
flange
handle for Starck
nut
cartridge
aerator
pop up rod
connection hose
fixing set
extension hose 300 mm
special tool set
(not part of delivery)
cold
97155000
10092000
97157000
96339000
94005000
97158000
96321000
13961000
13098000
96638000
58085000
hot

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis