Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Important! The fitting must be installed, flushed
and tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the basin.
3. Slip the plastic washer, the slide washer, the metall
washer and collar over the hoses and threaded
base and tighten the collar nut by hand. If there
is not enough space, please use only the slide
washer and the metal washer without the plastic
washer.
4. Tighten screws.
5. Connect the supply pipes to the isolation valves;
cold right - hot left.
The hot and cold supplies must be of equal pres-
sures.

Operation

The mixer is activated by lifting the lever handle.
Turning to the left
turning to the right = cooler water,
Technical Data
This mixer series-produced with
waterdimmer
(flow limiter).
®
Rate of flow with waterdimmer: 7 l/min 0,3 MPa
Rate of flow without waterdimmer: 11 l/min 0,3MPa
Operating pressure:
Recommended operating pressure: 0.1 - 0.5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Hansgrohe single lever mixers can be used toge-
ther with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0.15 MPa.
If the continuous water heater causes any problems or
there is not enough flow of water, the waterdimmer
(5a) located behind the aerator must be removed.

= warmer water,
max. 1.0 MPa
1.6 MPa
max. 80° C
65° C
English
To adjust the hot water limiter on single lever mixers,
please see page 20.
No adjustment is necessary when using a continuous
flow water heater.
Spare parts (see page 3)
1
handle
1.1 screw cover
2
flange
3
nut
4
cartridge cpl.
5
aerator cpl.
6
fixing set
7
connection hose 900 mm
®
32892XXX
96338000
97995XXX
97996000
92730000
13912000
95049000
96316000

Werbung

loading