Herunterladen Diese Seite drucken

Operation - HANSGROHE Mediano Thermostat 14241000 Montageanleitung

Eigensicher gegen rückfließen
Vorschau ausblenden Andere Handbücher für Mediano Thermostat 14241000:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Assembly
1. Flush through the supply pipes.
2. Mount the ball S - unions.
Hot water connection left hand, cold water
connection on the right hand side.
3. Fasten the mixer using ball union nuts, align
and tighten it. The ball S - unions enable
inaccuracies in the wall installation to be
compensated for, whether in the horizontal
direction, in the vertical direction or in the
parallel orientation.
4. Screw the escutcheons down the wall.
Large differences in pressure between the hot and
cold water supply should be balanced.
Adjustment
Correction is necessary if the temperature
measured at the take off point differs from the
temperature set on the scale. To adjust please see
page 11.

Operation

The mixer is operated by turning the handle on
the left hand side. The green knob limits the rate
of flow to approx. 10 l/min. If a higher water
consumtion is required press the ECOSTOP button
and turn handle further.
The temperature is selected by turning the
graduated handle on the right side. The flow of
the bath mixer can be changed from tub to
shower function by simply pulling the diverter
knob located at the top of the outlet.
When the water is shut off the flow returns
automatically to the bath function.
Temperature limitation
The temperature is limited by the safety check to
38° C (100° F). If a higher temperature is
required, it is possible to override the safety stop
by depressing the safety button.
6
English
The mixer is equipped with non return valves and
filters. If the water flow drops the non return
valves need to be cleaned. For that purpous the
mixer has to be removed from the wall. The filters
are located in the connection pieces underneath
the connecting nuts.
Attention!
The non return valves must be checked once a
year.
Using the thermostatic mixer in
conjunction with combination boilers.
When using the thermostatic mixer with
combination boilers, the Ecostop ring "A" has to
be removed.
If fitting a hand shower remove the water limiter
from the shower. (Please see page 12)
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 3 bars:
Spare parts
1
thermoelement
2
shut off unit
3
knob for thermoelement
4
knob for shut off unit
5
mousseur cpl.
6
spout cpl.
7
diverter knob
8
selector cpl.
9
non return valve DW 16
10 filter
11 ball s-unions
12 safety set for temperature control
13 safety set for flow control
14 non return valve DW 15
max. 10 bars
1 - 5 bars
16 bars
max. 80° C
65° C
20 l/min
94282000
94149000
92617000
92618000
13485000
92440000
94102000
94103000
95033000
95039000
13989000
94074000
6

Werbung

loading

Diese Anleitung auch für:

Mediano thermostat 14261000