Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning The Blade-Stop System Shield - Toro 20899 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 20899:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Cleaning the Blade-Stop
System Shield
Service Interval: Every 25 hours
1.
Disconnect the spark-plug wire from the spark
plug; refer to
Preparing for Maintenance (page
17).
2.
Tip the machine onto its side with the dipstick
down.
3.
Remove the 2 blade nuts and the stiffener
(Figure
50).
Figure 50
1. Blade nuts
2. Stiffener
3. Blade
4.
Remove the blade
5.
Remove the blade driver and the anti-scalp disk
(Figure
50).
6.
Remove the blade-stop system shield
50).
7.
Brush or blow out debris from the inside of the
shield and around all the parts.
8.
Install the blade-stop system shield that you
previously removed.
9.
Install the blade driver and anti-scalp disk that
you previously removed.
10.
Install the blade and the stiffener with the 2 blade
nuts that you previously removed
11.
Install the blade nuts.
Note:
Torque the blade nuts to 20 to 37 N∙m
(15 to 27 ft-lb).
4. Blade driver
5. Anti-scalp disk
6. Blade-stop system shield
(Figure
50).
(Figure
(Figure
g003133
50).
21

Werbung

Inhaltsverzeichnis
loading