outlet while the latch is released.
Fig. 13: Connecting a compressor installed in a cabinet
13. COMMISSIONING
Check if all fixing elements used during transport have been removed.
Check correct connection of compressed air (see chapter 11).
Check correct connection to the mains (see chapter 12).
Check position of the circuit breaker switch, it must be in position „I". If it is in position „0",
turn the switch (4) to position „I". (Fig. 14).
On DK50-10S/M (8 - 10bar) compressor, switch the switch (5) on the front side of the cabinet
to position „I", the green light indicates the device status in operation. (Fig. 14).
Check, if compressor cabinet (only 8 - 10 bar) is connected with the compressor by a cable
with a connector. (Fig. 13).
Check the connection of the the cabinet pressure gauge hose to the compressor pneumatic
block.
The compressor is not equipped with a backup power supply.
NP-DK50 PLUS, 2V-A-3_02-2020-MD
30
INSTALLATION
02/2020