PRODUCT MAINTENANCE
Fig. 22
A
B
400V
17.11. Procedure for connecting a compressor to a new cabinet
Prior to any maintenance or repair work, switch off the compressor and
disconnect it from the mains (pull out the mains plug).
The compressor in a cabinet requires that the jumper is not mounted in the terminal strip for correct
operation (Fig. 21, Fig.22, Pos. A). The switch on the cabinet switches the entire product on and off,
including the compressor.
If there is a jumper in the terminal strip, the switch on the compressor cabinet
will not work!
To connect a new cabinet to a compressor that previously worked without a cabinet, it is necessary
to cancel the connection in the compressor terminal strip by performing the procedure as follows.
(Fig. 21, Fig. 22). See also chap. 12.1 and 12.2.