Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Modes; Automatic Levelling; Accuracy Check Of The Measuring Tool - Bosch GLL 2-10 Professional Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für GLL 2-10 Professional:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
14 | English
Switch the measuring tool off when transporting it.
u
The pendulum unit is locked when the tool is switched off,
as it can otherwise be damaged by big movements.
Switching On/Off
To switch on the measuring tool, slide the on/off switch (3)
to the "  On" position (for working with the pendulum lock)
or to the "
 On" position (for working with automatic level-
ling). The status indicator (8) lights up. As soon as it is
switched on, the measuring tool emits laser lines from the
outlet apertures (2).
Do not direct the laser beam at persons or animals and
u
do not stare into the laser beam yourself (even from a
distance).
To switch off the measuring tool, slide the on/off switch (3)
to the "Off" position. The status indicator (8) goes out. The
pendulum unit is locked when the tool is switched off.
Never leave the measuring tool unattended when
u
switched on, and ensure the measuring tool is
switched off after use. Others may be blinded by the
laser beam.
If the maximum permitted operating temperature of 50 °C is
exceeded, the tool shuts down to protect the laser diode.
Once it has cooled down, the measuring tool is operational
again and can be switched back on.
Automatic shut-off
If no button on the measuring tool is pressed for approx.
120 min, the measuring tool will automatically switch itself
off to preserve battery life.
To switch the measuring tool back on after it has been auto-
matically switched off, you can either slide the on/off
switch (3) to the "Off" position first and then switch the
measuring tool back on, or press either the vertical mode
button (6) or the horizontal mode button (7) once.
To deactivate automatic shut-off, hold down the horizontal
mode button (7) for at least three seconds (with the measur-
ing tool switched on). If automatic shut-off is deactivated,
the laser lines will flash briefly as confirmation.
Note: If the operating temperature exceeds 45 °C, automatic
shut-off can no longer be deactivated.
To activate the automatic shut-off function, switch the meas-
uring tool off and on again.

Operating Modes

The measuring tool has several operating modes, which you
can switch between at any time:
– Cross-line mode (see figure C): Generates one horizontal
and one vertical laser line
– Horizontal mode (see figure D): Generates one horizontal
laser line
– Vertical mode (see figure E): Generates one vertical laser
line
After switching on, the measuring tool is in cross-line operat-
ing mode. Using the buttons for horizontal mode (7) and ver-
tical mode (6), you can switch the horizontal and vertical
laser lines on and off independently of one another.
1 609 92A 4HJ | (20.03.2020)
All operating modes can be selected with both automatic lev-
elling or the pendulum lock.

Automatic Levelling

Working with automatic levelling
Position the measuring tool on a level, firm surface or attach
it to the rotating mount (13) or the tripod (23).
For work with automatic levelling, slide the on/off switch (3)
to the "
 On" position.
The automatic levelling function automatically compensates
irregularities within the self-levelling range of ±4°. The level-
ling is finished as soon as the laser lines stop moving.
If automatic levelling is not possible, e.g. because the sur-
face on which the measuring tool stands deviates by more
than 4° from the horizontal plane, the laser beams will flash
quickly.
If this is the case, set up the measuring tool in a level position
and wait for the self-levelling to take place. As soon as the
measuring tool is within the self-levelling range of ±4°, the
laser beams will light up continuously.
In case of ground vibrations or position changes during oper-
ation, the measuring tool is automatically levelled again.
Upon levelling, check the position of the laser beams with re-
gard to the reference points to avoid errors arising from a
change in the measuring tool's position.
Working with the pendulum lock
For work with the pendulum lock, slide the on/off switch (3)
to the "  On" position. The pendulum lock indicator (9)
lights up red and the laser lines continuously flash slowly.
For work with the pendulum lock, automatic levelling is
switched off. You can hold the measuring tool freely in your
hand or place it on a sloping surface. This means that the
laser beams are no longer levelled and no longer necessarily
run perpendicular to one another.

Accuracy Check of the Measuring Tool

Influences on Accuracy
The largest influence is exerted by the ambient temperature.
In particular, temperature differences that occur from the
ground upwards can refract the laser beam.
Since the temperature stratification is greatest at ground
level, you should mount the measuring tool on a tripod and
position it in the centre of the work surface, wherever this is
possible.
In addition to external influences, device-specific influences
(e.g. falls or heavy impacts) can also lead to deviations. For
this reason, check the levelling accuracy each time before
beginning work.
First check the height accuracy and levelling accuracy of the
horizontal laser line, then the levelling accuracy of the ver-
tical laser line.
Should the measuring tool exceed the maximum deviation
during one of the tests, please have it repaired by a Bosch
after-sales service.
Bosch Power Tools

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis