Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Modes; Automatic Levelling; Accuracy Check Of The Measuring Tool - Bosch GCL 2-50 G Professional Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für GCL 2-50 G Professional:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Switching On/Off
To switch on the measuring tool, slide the on/off switch (4)
to the "On" position. As soon as it is switched on, the meas-
uring tool emits laser beams from the outlet apertures (1).
Do not direct the laser beam at persons or animals and
u
do not stare into the laser beam yourself (even from a
distance).
The measuring tool can be used with a laser receiver (19) at
any time.
To switch off the measuring tool, slide the on/off switch (4)
to the Off position. The pendulum unit is locked when the
tool is switched off.
Never leave the measuring tool unattended when
u
switched on, and ensure the measuring tool is
switched off after use. Others may be blinded by the
laser beam.
If the maximum permitted operating temperature of 45 °C is
exceeded, the tool shuts down to protect the laser diode.
Once it has cooled down, the measuring tool is operational
again and can be switched back on.
Automatic shut-off
If no button on the measuring tool is pressed for approx.
120 min, the measuring tool will automatically switch itself
off to preserve battery life.
To switch the measuring tool back on after it has been auto-
matically switched off, you can either slide the on/off
switch (4) to the "Off" position first and then switch the
measuring tool back on, or press the laser operating mode
button (3).
To deactivate the automatic shut-off function, hold down the
laser mode button (3) for at least 3 s (with the measuring
tool switched on). If the automatic shut-off function is deac-
tivated, the laser beams will flash briefly as confirmation.
Note: If the operating temperature exceeds 45 °C, automatic
shut-off can no longer be deactivated.
To activate the automatic shut-off function, switch the meas-
uring tool off and on again.

Operating Modes

The measuring tool has several operating modes, which you
can switch between at any time:
– Cross-line and point mode (see figure A): The measuring
tool generates a horizontal and a vertical laser line facing
forwards as well as two vertical laser points – one facing
up, the other down.
– Horizontal operation (see figure B): The measuring tool
generates a horizontal laser line.
– Vertical operation (see figure C): The measuring tool
generates a vertical laser line.
If the measuring tool is positioned in the room, the ver-
tical laser line is displayed on the ceiling beyond the up-
per laser point.
– Point mode: (see figure D): The measuring tool generates
two vertical laser points – one facing up, the other down.
Bosch Power Tools
To change the operating mode, press the button for laser op-
erating mode (3) as often as required until the laser beams
are generated in the required operating mode.
All operating modes can be used with both automatic level-
ling and the incline function.
All operating modes are suitable for operation with the laser
receiver (19).

Automatic Levelling

The measuring tool monitors the position at all times during
operation. It works with automatic levelling during set-up
within the self-levelling range of ±4°. Outside of the self-lev-
elling range, it will automatically switch to the incline func-
tion.
Working with automatic levelling (see figures A–D)
Position the measuring tool on a level, firm surface or attach
it to the rotating mount (11) or the tripod (21).
The automatic levelling function automatically compensates
irregularities within the self-levelling range of ±4°. Once the
laser beam is permanently lit, the measuring tool has levelled
in.
If automatic levelling is not possible, e.g. because the sur-
face on which the measuring tool stands deviates by more
than 4° from the horizontal plane, the laser lines will initially
flash quickly for 2 seconds, then quickly flash every
5 seconds several times. The measuring tool is in the incline
function.
For additional work with automatic levelling, set up the
measuring tool so that it is horizontal and wait for the self-
levelling procedure to complete. As soon as the measuring
tool is within the self-levelling range of ±4°, the laser beams
will light up continuously.
In case of ground vibrations or position changes during oper-
ation, the measuring tool is automatically levelled again.
Upon levelling, check the position of the laser beams with re-
gard to the reference points to avoid errors arising from a
change in the measuring tool's position.
Working with the Incline Function (see figure E)
Place the measuring tool on an inclined surface. When work-
ing with the incline function, the laser lines will initially flash
quickly for 2 seconds, then quickly flash every 5 seconds
several times.
In the incline function, the laser lines are no longer levelled
and no longer necessarily run perpendicular to one another.

Accuracy Check of the Measuring Tool

Influences on Accuracy
The largest influence is exerted by the ambient temperature.
In particular, temperature differences that occur from the
ground upwards can refract the laser beam.
Since the temperature stratification is greatest at ground
level, you should always mount the measuring tool on a tri-
pod for measuring distances of 20 m or more. In addition,
position the measuring tool in the centre of the work surface,
wherever this is possible.
English | 17
1 609 92A 5EN | (20.03.2020)

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis