Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Modes; Initial Operation - Bosch BL 100 VHR Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Control indicators and unit elements
18 Battery compartment lid
19 Unit number
20 Socket for charger plug
21 Guarantee seal
22 Tripod connections 5/8" (2x)
23 Battery charger and adapter
24 Spare batteries
25 90° dual-beam prism
26 BLE 100 Receiver with universal holder
27 Remote control BLR 10
28 Remote control/receiving combination BLF 10
29 BLM 260 Construction laser measuring rod
30 Tripod BS 280 M
31 Measuring plate with angle base
32 Ceiling measuring plate
33 Wall mount
34 Laser viewing glasses
35 Carrying case
Not all of the accessories illustrated or described are
included as standard delivery.
Tape Measure Care
When the unit has experienced strong impacts to
its exterior, always perform an accuracy check
before continuing to work (see Section "Levelling
Accuracy").
The unit can be used indoors and outdoors. It is
drip-proof, however, not 100 % watertight; therefore
do not immerse the unit into water and protect from it
rain.
Do not expose the unit to extreme temperatures and
temperature variations (e. g., do not leave in vehi-
cles).

Operating Modes

The unit is a full automatic rotational laser with leveling
automatic both in horizontal and vertical position.
horizontal
position
Rotation operation
is mainly used in conjunction with the
BLE 100 receiver and the BLF 10 remote
control/receiving
sory). Four rotational speeds can be se-
lected.
14 • 1 609 929 785 • TMS • 17.04.01
vertical
position
combination
(acces-
English - 2
Point operation
is mainly used for the easy projection of
heights. Resetting the laser beam can be
carried out manually, with the arrow
push-buttons and with the remote con-
trol 27 (accessory).
Standard beam
In this operation mode the laser beam
moves fix-programmed within a limited
operating range.
This clearly increases the visibility of the
laser.
Programmable line
The function meets that of the standard
line. However, the starting and end point
of the line can be chosen variably
(e. g. for larger working range).

Initial Operation

Before initial operation, charge the batteries as de-
scribed in Section "Charging/Replacing Batteries".
Set up the unit in accordance with the selected opera-
tion mode or mount on a tripod (accessory).
Set the deflection prism 4 on the rotor plate 2.
Switching on: Press the On/Off switch 17.
The operation indicator 14 lights up and the au-
tomatic leveling begins (see Section "Leveling
Automatic").
The unit is ready for operation as soon as the laser
beam and the leveling indicators 13 and 11 light up con-
tinuously. Now the operating modes can be selected
(see Section "Operation").
Switching off: Press the On/Off switch 17.
When exceeding the maximum allowed operat-
ing temperatur of 45 °C, the unit automatically
switches off in order to protect the laser diode. Af-
ter cooling down, the unit is ready for operation
again and can be switched on.
Operation
Rotational Operation
Press push-button 15 to switch the rotation on.
Each additional pressing of the push-button 15
reduces the speed in four steps to standstill.
Due to the high measuring accuracy the levelness of the
unit can be interupted by pressing the operating
push-buttons. The rotor stops, but continues to turn after
briefly releveling. By using the remote control 27 (acces-
sory) this effect can be avoided. If the push-button 15 is
pressed for a few seconds upon switching on, the rotor
also rotates during the leveling procedure.
This function can also be activated with the remote con-
trol 27 (accessory) (see instructions for BLR 10).

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis