Verfügbare Sprachen

Verfügbare Sprachen

Safety semiconductor outputs
Number
SCB-02 (all variants)
SCB-03 (all variants)
SCB-04 (all variants)
Structure
Switching capacity per output
Max. capacity load
Max. Pulse duration for selftest
Galvanic isolation
Short-circuit-proof
Max. switch-off delay
Output voltage at "1" (max. load)
Safety relay outputs
Number
SCB-02 (all variants)
SCB-03 (all variants)
SCB-04 (all variants)
Switching capacity per contact
(0,1 Hz)
Minimum contact load
Contact fuse
Contact material
Contact service life
Auxiliary outputs:
Number
Structure
Switching capacity per output
SCB-02 (all variants)
SCB-03 (all variants)
SCB-04 (all variants)
Galvanic isolation
Short-circuit-proof
Output voltage at „1" (max. load)
Environmental data
Ambient temperature
Storage temperature
Humidity rating
Vibrations as per EN 60068-2-6 - Frequency
Vibrations as per EN 60068-2-6 - Acceleration
EMC
Air and creepage distance
Overvoltage category
Degree of soiling
Rated insulation voltage
Rated surge voltage strength
H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Deutschland • Tel +49 241 9105010
Fax +49 241 91050138 • info@zander-aachen.de • www.zander-aachen.de
38
Safety Time Control Device SCB
0
3
2
PNP outputs, diverse
U
/ 500 mA
B
0.5 µF per 10 mA output current
< 3 ms
no
yes
160 ms (+ configured delay times, if applicable )
U
- 1 V
B
2
0
2
AC:
250 V, 1000 VA, 4 A for resistive load
DC:
50 V, 200 W, 4 A for resistive load
AC-15: 2 A / AC 250 V; DC-13: 3 A / DC 24 V
UL:
C300 / R300
10 V / 10 mA
6 A gG; Factor 0.6 for applications acc. to EN 50156-1
(See Chapter 10.5.5.3.4)
AgNi; AgSnO2
7
mech. 1x10
switching cycles
2
PNP outputs, single channel
C1: U
/ 200 mA; C2: U
B
B
C1: U
/ 500 mA; C2: U
B
B
C1: U
/ 500 mA: C2: U
B
B
no
yes
U
- 1V
B
0 °C to +55 °C - see derating characteristic curves
-20 °C to 85 °C
93 % RH at +40 °C, non-condensing
5 Hz to 150 Hz
1 g
EN 61326-3-1
As per EN 60664-1
|||
(DIN VDE 0110-1)
2
(DIN VDE 0110-1)
50 V (For SELV/PELV circuit)
250 V (Between relay circuit and SELV/PELV circuit)
800 V - Basic insulation for SELV/PELV circuit
6 kV - Safe insulation, reinforced insulation between
relay circuit and SELV/PELV circuit
/ 50 mA
/ 50 mA
/ 50 mA