Installation, commissioning, maintenance, and decommissioning should be done only by
authorised and qualified technicians:
− who are familiar with proper handling of the safety components
− who are familiar with the applicable EMC and ESD regulations
− who are familiar with the local regulations concerning work safety and accident
prevention
− who have read and understood these operating instructions.
Opening the device, any kind of manipulation to it and bypassing the safety devices are
not permitted
The electrical connection of the device must take place only when the voltage supply is
switched off
Loads at the outputs must be disconnected from the device during device configuration
The wiring of the device must be according to the instructions of this user information,
otherwise there is a risk that the safety function will be lost
The current paths 17-18 and 27-28 must carry only the same voltage potentials
The device version (see nameplate "Ver.") should be stored and checked before every
commissioning. When there is a version change, the use of the device in the overall
application should be revalidated

4. Appropriate use

The SCB is a universally applicable safety time control device, with which the moving
parts of a machine or plant can be brought to a standstill quickly and safely in case of dan-
ger. Depending upon the configuration, the safety outputs connect on-delay, off-delay or
without delay independent of one another.
The approved operating parameters for use must be complied (see "Technical data").
A risk assessment should be carried out on the machine before using the device. For
example, according to:
EN ISO 13849-1, Safety-related parts of control systems, Appendix A
EN ISO 12100, Safety of machinery - General principals for design - Risk assessment and
risk reduction
IEC 62061, Safety of machinery - Functional safety of safety-related electrical, electronic
and programmable electronic control systems.
Additional requirements may have to be considered depending on the type of machine or
plant.
H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Deutschland • Tel +49 241 9105010