2. to 5. PIN entry
The access to PIN Entry is signalled by the indication „Pn". The first digit of the PIN is
shown as blinking. The first digit of the PIN is set by turning the push/rotary button. The
first PIN digit is saved by pressing the button briefly and the second PIN digit can be set in
the same way as the first one. The PIN entry is ended by pressing the button briefly.
INFO: The PIN of the SCB is: 4 - 2
In case of wrong PIN entry, an error indication „Er18" appears. The error should be
acknowledged by pressing the button for 2 s.
ATTENTION: After acknowledgement, the SCB goes back into the operating mode. If the
starting behaviour "automatic reset" is selected and the safety circuit closed, the SCB will
be activated immediately
6. Parametrizing the delay time
After successful PIN entry, the delay time can be set by turning the push/rotary button.
The delay time is confirmed and saved by pressing the button for 2 s.
TIP: To abort the parametrising, disconnect the supply voltage of the device.
7. System restart
The SCB applies the delay time.
ATTENTION!
Make sure that the supply voltage of the device is safely applied during loading the new
configuration. A power-off during the loading process leads to a non-acknowledgeable
error condition. In this case, the device must be returned to the manufacturer
If the starting behaviour "automatic reset" is selected and the safety circuit closed, the
SCB will be activated immediately
H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Deutschland • Tel +49 241 9105010