Herunterladen Inhalt Inhalt Diese Seite drucken

Timing Diagrams; Timing Diagram Scb-04 With Configuration Pr04 - Zander Aachen SCB Serie Betriebsanleitung

Vorschau ausblenden Andere Handbücher für SCB Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Safety Time Control Device

17 Timing diagrams

17.1 Timing diagram SCB-04 with configuration Pr04

Table 10 shows the corresponding extract from the configuration table.
Configuration No.
Auto
Man.
reset
reset
04
Table 10: Extract from Configuration table SCB-04 - Configuration Pr04
Legend : F1: AUX C1 serves as immediate output for the time-delayed safe outputs/contacts
F2: AUX C2 serves as fault signaling
Figure 24 shows the timing diagram for Configuration Pr04.
Figure 24: Timing diagram for SCB-04 with Configuration Pr04 (Qualitative representation)
t
:
Power supply activation
1
t
:
Safety circuit I11/I12 is closed
2
t
:
Output O1 and C1 are switches on immediately (reaction time)
3
t
:
After the parametric delay time has elapsed, output O2 and the relay contacts 17-18/27-28 switches on
4
t
:
Requirement of the safety function by opening the safety circuit at I11/I12
5
t
:
Outputs O1 and O2, relay contacts 17-18 / 27-28 and C1 switches off without any delay time
6
t
:
Safety circuit I11/I12 is closed
7
t
:
Output O1 and C1 are switches on immediately (reaction time)
8
t
:
After the parametrized delay time has elapsed, output O2 and the relay contacts 17-18/27-28 switches on
9
t
: Power supply is switched off. All outputs and relay contacts switch off immediately
10
H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Deutschland • Tel +49 241 9105010
Fax +49 241 91050138 • info@zander-aachen.de • www.zander-aachen.de
Non-delayed
outputs/contacts
Man. reset
with autom.
O1
O2
17/18
re-triggering
Delayed
outputs/contacts
27/28
O1
O2
17/18
27/28
AUX Function
Delay type
C1
C2
F1
F2
On-delay
31