15. Diagnostic functions

The SCB has several diagnostic options. In addition to a two-digit display, which shows
the currently parameterized delay time and configuration as well as error messages, three
status LEDs are available for the IO status display.
Table 3 explains the symbols of the status LEDs used in the following.
15.1 Operating state with Off-delay outputs/contacts
In the operating state, the current status of the SCB is shown on the display and the
LEDs.
1.
9 s
Y1
Y1
1. Power-On
After the supply voltage is applied, the SCB carries out a self-test (duration approx. 9 se-
conds). At the same time, each individual segment is controlled on the display, whereby
the display can be checked for possible errors.
TIP: Checking the display before re-parametrising avoids possible incorrect settings due
to display errors.
H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Deutschland • Tel +49 241 9105010
Fax +49 241 91050138 • info@zander-aachen.de • www.zander-aachen.de
24
Safety Time Control Device SCB
Status
Description of the status
LED
I11/I12: Low at input.
Out:
Safety outputs not switched.
I11/I12: High at input.
Out:
Safety outputs not switched.
Out:
Time-delay of outputs is running.
Table2 - Symbol explanations Status-LED's