TRP 100 M, TRP 100 W
Press
or
to select the FROST symbol. The
FROST symbol flashes. Press the ENTER key.
FROST symbol and temperature 7° C are
displayed.
10.5
Runback timer
The runback timer enables the user to activate a one-
off, time-limited heating program.
ON OFF
Press the MENU key. The TIMER symbol flashes.
Press the ENTER key. The ON symbol flashes.
Press
or
to select the OFF symbol. The OFF
symbol flashes.
Press the ENTER key =>Heating operation off.
Press the FORWARD key. Heating operation takes
place for 30 minutes (factory setting).
Where necessary, change the room temperature
with
or
.
To end prematurely, switch off the heating device.
Heating duration runback timer
The maximum heating duration, limited to 2 hours at
the factory and adjustable in four stages of 30 minutes
each, can be changed as shown in the table.
Press and hold the MENU key and the FORWARD
key for five seconds.
rb display flashes.
www.dimplex.de/en
ON
10.6
This function can be used to ensure that a minimum
room temperature is specified even during OFF times,
for example in timer mode (week program).
The specification also applies for the runback timer
function. Frost protection mode has priority.
ON OFF
1810/B
Press the ENTER key. The ON symbol flashes.
Press the ENTER key. The heating duration
program flashes. For variants, see table, left
column (factory setting 2 h).
Press
or
to select the desired heating
duration program. Press the ENTER key. The room
temperature flashes.
Use
or
to set the room temperature and
confirm with ENTER.
Confirm the BACK key to return to the standard
display.
Heating
Press the FORWARD key:
duration
program
1 time
30 minutes
00:15
01:00 h
00:15
01:30 h
00:15
02:00 h
00:30
(factory)
04:00 h
01:00
06:00 h
01:30
08:00 h
02:00
Minimum room temperature
NOTE
NOTE
Press and hold the MENU key and the FORWARD
key for five seconds. rb display flashes.
Press the
key The display Sb flashes.
English
2 times
3 times
4 times
00:20
00:25
00:30
00:30
00:45
01:00
00:30
01:00
01:30
01:00
01:30
02:00
02:00
03:00
04:00
03:00
04:30
06:00
04:00
06:00
08:00
ON OFF