Menu no.
Parameter /
info
Running
time CP
3.11
manual
mode
Menu no.
Parameter /
info
Information
4.00
Current
4.02
pressure
value
Current
4.04
valve states
Current wa-
ter level
4.08
rainwater
storage tank
Current wa-
ter capacity
4.09
rainwater
storage tank
Total run-
4.12
ning time of
the panel
MP running
4.13
time
CP running
4.14
time
Total cycles
4.17
of panel
MP switch
4.18
cycles
CP switch
4.19
cycles
Switchgear
4.22
serial num-
ber
Software
4.24
version
Menu no.
Parameter /
info
Installation
5.00
Pump type
5.04
Number of
5.05
CP
Installation and operating instructions Wilo-RAIN3
Description
Min.
Max. Text
0
180
Min.
Max. Text
0.0
10.0
Rain water Tap wa-
ter; Auto
0
1000
0
100
0
0429
4967
295
0
6553
5
0
6553
5
0
6553
5
0
6553
5
0
6553
5
0
9999
9999
9
0
9999
Parameters such as the rainwater storage tank dimensions have to be set in this
menu
Min.
Max. Text
HiMulti3-24; HiM-
ulti3-25; HiM-
ulti3-45
0
1
Default
Unit
Ac-
Description
cess
level
120
s
2
Running time of CP in manual mode; after
running time the CP mode will be OFF; 0s
means unlimited running time
Default
Unit
Ac-
Description
cess
level
1
The current operating values of panel and
pumps
bar
1
The current pressure as reported from the
pressure sensor
1
The state of installed valves can be shut,
open or automatic
cm
1
The current level of rainwater in the rain-
water storage tank
%
1
The calculated value of water capacity in
cistern if shape of the rainwater storage
tank is specified in the menu
0
h
1
Total operating time. Time pulse in back-
ground counts in minutes unlike the dis-
play unit.
0
h:mi
1
Operating time of MP
n
0
h:mi
1
Operating time of CP
n
0
1
The number of power-on cycles for the
panel
0
1
The number of power-on cycles for MP
0
1
The number of power-on cycles for CP
0
1
ID of the panel
V5.000
1
The software version of the installed ap-
plication
Default
Unit
Ac-
Description
cess
level
1
The settings regarding the installation of
the panel in a system
Last setting
3
Select of pump type to define pump
will be used
curves to get optimized set pressure for
switch-off refer in menu 1.05
0
2
Contains the number of pumps dedicated
to a cistern
en